DISTRIBUTORS

B2

B2

.118

CM CLEVER MULTIMACH

INPUT MODULES

With a suitably arranged Clever Center, you can insert add-on modules.

When connecting buses, the add-on modules can only be used for e PNP INPUTs.

With a multi-pole connection, the following INPUTs and OUTPUTs can be used:

• DIGITAL INPUTS, as cylinder sensors for example

• DIGITAL OUTPUTS

• ANALOGUE INPUTS (but the LEDs do not light up)

• ANALOGUE OUTPUTS (but the LEDs do not light up)

They can be combined, even on the same module. You can choose between PNP or NPN connections via a dip switch-type selector.

All the INPUTS/OUTPUTS must be the same type, i.e. all PNP or NPN.

MAXIMUM EXTENSION OF ADD-ON MODULES

Up to 4 modules can be connected, giving a total of 32 input signals.

Ordering code

A yellow LED for each input/output

(visible for digital types)

0227302900