Table of Contents Table of Contents
Previous Page  657 / 1486 Next Page
Information
Show Menu
Previous Page 657 / 1486 Next Page
Page Background

A6

ACTUATORS

A6

.17

LTL POSITION SENSOR

DIMENSIONS AND ELECTRICAL CONNECTION

FIXING ON THE ACTUATOR AND START-UP

Type

L [mm]

L1 [mm]

LTL-287

289

287

LTL-359

361

359

LTL-431

433

431

LTL-503

505

503

1. Position the brackets (code W0950000721) in one of the T-slots in the cylinder liner (fig. A);

2. Fix the brackets in the position sensor slot at least 30 mm from the ends of the position sensor (fig. B). The brackets are used to adjust the position

along the axis of the piston rod, including perpendicular to the T-slot (fig. C). This allows you to fix the position sensor in as central a position as

possible (fig. D);

3. Connect the position sensor to the power supply using the M8x1 4-pin connector, wiring the voltage or the current output;

4. If you wish to determine a specific measuring range, perform the procedure with the Teach pad ( ) (see user manual).

N.B.

If a measuring range is not set, the maximum range is used automatically.

L

= Total length

L1

= Measuring range

3 4

2

1

8,2

L

19,5

2,6

0,7

1,3

L1

20

±0,20

7,5

14

±0,20

LTL

TEACH PAD button

LED1 (yellow/red)

LED2 (blue/green)

PIN Colour

Function

1

Brown

Voltage +

2

White

Current output

3

Blue

Voltage -

4

Black

Voltage output

30 min

GRAPH OF THE VOLTAGE OR CURRENT ANALOGUE OUTPUT SIGNAL VALUE AND THE OUT-OF-RANGE VALUE

Out of range

Out of range

Out of range

Out of range