A6

ACTUATORS

A6

.11

LTS POSITION SENSOR

LTS POSITION SENSOR

The LTS is a magnetic position sensor for measuring linear strokes of

actuators. The position of the piston is measured without contact and

given via a configurable analogue output signal, as voltage or current.

The body of the LTS is very compact, so it can be used in applications

where limited space is available.

This position sensor can measure the strokes of various families of

actuators up to 256 mm.

Correct operation requires a magnetic field strength of between 4 and

30 mT.

The measurement range can be regulated accurately using the Teach-in

button (zero point and end point). Teach-in can be performed regardless

of the polarity of the magnetic field and the position of the sensor. The

yellow ON light comes on when the piston is in measuring range.

The position sensor is out of the measuring range when:

• the yellow light is off; and

• the voltage signal is 11V (range 0-10V) or the current 3 mA

(range 4-20 mA).

TECHNICAL DATA

Measuring length (± 1 mm)

mm

from 0 to 256

Electrical connection

M8x1 – 4 pin

Electromagnetic compatibility in accordance with standard

EN 60947-5-7

Sample time

ms

1

IEC 60068-2-6 shock test

30 g, 11 ms

IEC 60068-2-6 vibration test

10 Hz ... 55 Hz, 1 mm

Maximum displacement speed

m/s

< 3

Linearity*

mm

0.3

Resolution

mm

0.03 % FSR (≥ 0.05 mm)

Repeatability

mm

0.06 % FSR (≥ 0.1 mm)

Operating temperature

°C

–20 to +70

Index of protection

IP 67

Protection class

III

Voltage

V

15 - 30

Black current (without load)

mA

< 25

Analogue output (voltage)

V

0 to 10

Out-of-range analogue output

V

11

Analogue output (current)

mA

4 to 20

Out-of-range analogue output

mA

3

Max. load resistance (current output)

Ω

500

Min. load resistance (voltage output)

Ω

2000

Polarity inversion protection

YES

Short-circuit protection

YES

Overload protection

YES

* In some applications, linearity may be higher than the value

indicated.

#TAG_A6_00070