Table of Contents Table of Contents
Previous Page  1375 / 1464 Next Page
Information
Show Menu
Previous Page 1375 / 1464 Next Page
Page Background

ACCESSORIES

E4

E4

.11

DIMENSIONS AND ORDERING CODES

The Timer is part of Metal Work range of logic elements, which also

includes OR, AND, NOT, YES, MEMORY.

The value of the signal output delay is set by rotating a knob. It can work

both as 3/2 NC and 3/2 NO, depending on whether feeding is through

port “a“ or port “b”.

The maximum delay time can be increased by unscrewing a plug

and connecting the port to an external auxiliary tank.

• Adaptor for Ω bar (DIN EN 50022) integrated in the body.

• Pressure indicator via an orange pin

• Pipe clamping system using Ø 4 built-in push-on fittings.

TECHNICAL DATA

Temperature range

°C

Valve coupling

mm

Pressure range

bar

Nominal diameter

mm

Flow rate at 6 bar (0.6 Mpa, 87 psi) ΔP 1 bar (0.1 Mpa, 14.5 psi)

Nl/min

Delay setting range

s

Signal shutoff time

s

Repeatability

s

Fluid

Operating

Repositioning

Installation

Assembly

MATERIALS

Body

Internal parts

Gaskets

Spring

– 10 to + 60

Push-in fitting for Ø 4 pipe

From 2.5 to 8

2.7

100

From 0 to 30, at 6 bar

< 0.1

± 0.4

Filtered, lubricated or unlubricated compressed air. If used, must be continuous

By compressed air

By mechanical spring

In any direction

On Ω bar (DIN EN 50022) size 35 x 7 o 35 x 15 - Wall mounting using Ø 4.2 holes

Anodised aluminium / Technopolymer

Brass / Technopolymer

NBR

Spring steel

TIMER

TIMER

Code

Description

W3604000006

Timer

#TAG_E4_00070