Table of Contents Table of Contents
Previous Page  1349 / 1416 Next Page
Information
Show Menu
Previous Page 1349 / 1416 Next Page
Page Background

ACCESSORIES

E5

E5

.21

FIXING

COMPONENTS

PNEUMO-POWER

Aluminium body, treated and painted

Aluminium body, treated and painted

Aluminium base, treated and painted

Brass nozzle

Turbine and electrical generator unit

M8 3-pin connector

NBR gaskets

Electronic board

Vibration dampers

Silencer

The generator can be fixed on a flat surface using

the 3 M4x10 screws (fig ), and the 3 vibra-

tion dampers supplied with the device (fig. )

FUNCTION DIAGRAM

The compressed air is supplied via a nozzle

that converts pressure energy into kinetic energy.

The supersonic jet of air strikes the blades

of a micro-turbine, which is integral with an

electrical generator. An electronic power

management unit ensures constant voltage

output at varying input pressures and applied

electrical loads. The electrical power thus

generated can supply any type of utility.

Nozzle

Micro-turbine

COMPRESSED AIR

24 VDC

Power control unit

Electric generator