GENERAL CATALOGUE
Table of Contents Table of Contents
Previous Page  1216 / 1464 Next Page
Information
Show Menu
Previous Page 1216 / 1464 Next Page
Page Background

UNITS

C6

C6

.6

Proportional pressure regulators series REGTRONIC have the job of

precisely regulating the pressure in a system, the variables depending

on the input command.

Remote control regulators are controlled by

means of an M12x1 cable and connector and can have Volt, mA or

RS232 control. Regulators with a display can be controlled via a cable or

directly using the keys below the display.

The pressure value and a series

of information and diagnostics are visible at all times on the graphic

display.

The user-display interface, LEDs and buttons are all on one side.

The programming and reading software is comprehensive, simple and

intuitive. Pressure control takes place in a “closed-loop” with an electronic

precision pressure sensor that measures the downstream pressure, a

control system that compares it with the desired pressure, and two mini

solenoid valves that adjust the pressure to reach the target value.

PROPORTIONAL PRECISION PRESSURE REGULATOR REGTRONIC SERIES

PROPORTIONAL PRECISION PRESSURE REGULATOR

REGTRONIC SERIES

TECHNICAL DATA

REGTRONIC

REGTRONIC

NEW DEAL

REGTRONIC

300

REGTRONIC

400

Threaded port

M5 1/8’’

1/4’’

3/4’’

1’’

1/2’’

3/4’’

1’’

1’’

1 1/4’’ 1 1/2’’

2’’

Fluid

Filtered, unlubricated air. The air must be filtered at least 10 μm

MIN inlet pressure

bar

Regulation pressure + 1 bar

MAX inlet pressure

bar

11

Temperature range

°C

0 - 50

Pressure regulation range

bar

0.05 - 10 (settable full scale and minimum pressure)

Flow rate at 6.3 bar ΔP 0.5

Nl/min 10 770 1490

10000

4500

18000

20000

Flow rate at 6.3 bar ΔP 0.1

Nl/min 10 1050 1700

13000

7000

-

-

Exhaust flow rate at 6.3 bar with 0.1 bar overpressure

Nl/min 2 320 500

1800

250

400

400

Exhaust flow rate at 6.3 bar with 0.5 bar overpressure

Nl/min 9 650 1200

2000

500

850

850

Weight

kg 0.2 0.38 0.38

1.3

1.5

5

5.8

Class of protection

65

Power supply

24 Vcc +10% -5% I max 110 mA

Input signal (input impedence)

Voltage

0 - 5 Vcc, 0 -10 Vcc (approx. 6.3 KΩ)

Current

4 - 20 mA (approx. 100 Ω)

Serial ports

RS 232

Manual

Keypad

Output signal

Analog

0 - 10 Vcc (1 V=1bar) - 1 mA max

Digital

PNP open collector output: max 24V 60 mA

NPN open collector output: max 24V 60 mA

Linearity

≤ ± 0.5% (Full scale)

Hysteresis

≤ ± 0.2% (Full scale)

Repeatability

≤ ± 0.2% (Full scale)

Sensitivity/Dead-band

setting range 10 - 100 mbar

Output pressure (display version)

Accuracy

≤ ± 0.3% (Full scale)

Unit of measurement

bar, MPa, psi

Minimum resolution

0.01 bar - 0.001 MPa - 0.01 psi

Analog output accuracy

≤ ± 0.4% (Full scale)

Temperature characteristics

max 2 mbar / °C

Response time with ΔP =1 bar

volume 100 cc

volume 1000 cc

from 6 to 7 bar

s 0.5

0.2

0.3

0.45

0.35

from 7 to 6 bar

s 0.55

0.3

0.3

0.45

0.7

Installation position

In any position

Notes

The features shown refer to the static condition only. With air consumption on the output side, the pressure may vary.

On all versions you can set the parameters using the software “MWRegtronic” downloadable

from the website

www.metalwork.eu

.

To connect the PC to Regtronic you can use the cable code W0970513019.

#TAG_C6_00020