UNITS

C3

C3

.43

The 2/2 progressive valve comes in two versions, with solenoid or pneumatic

actuation.

STD progressive start valve:

a differential balanced valve automatically opens

the air port fully when the downstream pressure is about 50% of the upstream

pressure.

Progressive start valve with pneumatic or solenoid actuation:

without a pilot,

the upstream air flows downstream through the regulation needle.

When an external or pneumatic solenoid signal is generated, the valve opens

the main port to create full flow. It does not relieve the downstream circuit.

TECHNICAL DATA

Threaded port

Min. inlet pressure **

MPa

bar

psi

Max. inlet pressure*

MPa

bar

psi

Flow rate at 6 bar (0.6 MPa to 87 psi) ΔP 0.5 bar (0.05 MPa to 7 psi)

Nl/min

scfm

Flow rate at 6 bar (0.6 MPa to 87 psi) ΔP 1 bar (0.1 MPa to 14 psi)

Nl/min

scfm

Max temperature

°C

°F

Weight

kg

Wall fixing screws

Mounting position

Type of control

Fluid

** 0.01 MPa – 0.1 bar – 1.45 psi for pneumatic and pilot-assisted versions

with controls at min. 0.3 MPa 3 bar 43.5 psi.

* 1 MPa – 10 bar – 1.45 psi

VAP 100

1/4”

3/8”

0.3

3

43.5

1.5

15

217

1300

46

2000

71

50

122

0.5 ~

M4 x 50

In any position

Automatic - Pneumatic – Solenoid – Solenoid pilot-assisted

Filtered, lubricated or unlubricated compressed air. Lubrication, if used, must be continuous

Skillair

®

PROGRESSIVE START VALVE

PROGRESSIVE START VALVE

#TAG_C3_00150