Table of Contents Table of Contents
Previous Page  1021 / 1486 Next Page
Information
Show Menu
Previous Page 1021 / 1486 Next Page
Page Background

UNITS

C1

C1

.15

Syntesi

®

ACTIVE CARBON FILTER

Activated-carbon filtering systems achieve the highest standard of

purification possible in industrial applications. They eliminate all traces

of oils, solvents and hydrocarbons, and remove unpleasant odours.

The operating principle uses activated carbon, which absorbs most of

the polluting particles in the air thanks to minute holes in the granules of

carbon.

On the front and back there is a port (1/8” for size 1 and 1/4” for

size 2) that can be used with pressure gauges, pressure switches or as an

additional air intake.

The air taken from here is not filtered by the

activated-carbon cartridge

.

Cartridge life and efficiency can be increased by using pre-filtered (5μm)

and purified (0.01μm) air.

The cartridge must be replaced at set intervals as there is no difference

in load loss between an efficient cartridge and a saturated one.

N.B.: to ensure the performance and duration stated on the data sheet,

the load loss (ΔP) must not exceed 75 mbar.

ACTIVE CARBON FILTER

COMPONENTS

Technopolymer depurator body

IN/OUT bushing made of OT58 nickel-plated brass

or passivated aluminium for 3/4” - 1”

Active carbon cartridge

Technopolymer cartridge support

Drain (RMSA)

Technolpolymer plate

NBR o-ring gasket

Clear technopolymer bowl

TECHNICAL DATA

Threaded port

Residual oil at 20°C *

mg/m

3

Duration of cartridge *

hours

Max. inlet pressure

bar

MPa

psi

Suggested flow rate at 6.3 bar (0.63 MPa; 91 psi)

Nl/min

scfm

Min/max temperature at 10 bar; 1 MPa; 145 psi

°C

Weight

g

Condensate drain

Fluid

Mounting position

Additional air take-off port (unfiltered air from cartridge CA)

Additional air take-off flow rate at 6.3 bar

Nl/min

(0.63 MPa; 91 psi) ΔP 1 bar (0.1 MPa; 14 psi)

scfm

Wall fixing screws

Notes on use

* if the load loss of 75 mbar is not exceeded

1/8’’

1/4’’

3/8’’

3/8”

1/2”

3/4”

1”

0.003 - output air purity class ISO8573-1: 1.7.1

4000

4000

15

13

1.5

1.3

217

188

350

800

12

28

N.B.: flow rates higher than the recommended value reduces purification efficiency

From -10 to +50

From -10 to +50

195

190

181

483

456

452

440

RMSA: drain with manual condensate discharge and automatic discharge at zero pressure

0.01 μm filtred and depurated air

In any position

In any position

1/8”, front and rear

1/4”, front and rear

500

1500

18

53

No. 2 M4 screws

No. 2 M5 screws

Upstream it’s necessary to mount a coalescence filter depurator of 0.01μm.

FIL CA SY1

FIL CA SY2

#TAG_C1_00050